Self Contain Freezer Chiller Unit |
|
 |
Features/Benefits |
-
-
- |
Our self cotain cooler is compact in structure. It save
installation space and cost.
The integrates evaporator, condenser, compressor
and electrical control units are in one compact body.
This unit include Heat exchangers of high efficient in
grooved copper tube with aluminum fins, The intelligent
controls are with automatic temperature set,
temperature control. The protection devices are over
loading, sub-heating, lack of phase, high & low
pressure, hot gas defrosting, Refrigerant R404a and etc. |
 |
|
|
|
Capacity Range From: |
0.2 - 1.5 Tons |
For More Detail: |
Download |
|
MODEL: SLYCJ-___-MY-P |
33 |
50 |
63 |
100 |
125 |
175 |
200 |
275 |
Rated Cooling capacity |
BTUH |
1,808 |
2,764 |
3,583 |
5,323 |
7,609 |
10,065 |
11,089 |
15,013 |
Tons |
0.2 |
0.2 |
0.3 |
0.4 |
0.63 |
0.84 |
0.92 |
1.25 |
Watt |
530 |
810 |
1,050 |
1,560 |
2,230 |
2,950 |
3,250 |
4,400 |
Power Supply |
V/P/Hz |
220V / 1P / 50Hz |
415V / 3P / 50Hz |
Power Input |
Watt |
680 |
850 |
1,100 |
1,300 |
1,750 |
2,520 |
2,610 |
3,330 |
Temperature Range |
Deg. C |
0 - 5 |
Condenser Fan Power Input |
Watt |
1 x 75 |
1 x 75 |
1 x 75 |
1 x 80 |
1 x 80 |
1 x 155 |
1 x 155 |
2 x 80 |
Evaporator Fan Power Input |
Watt |
1 x 75 |
1 x 75 |
1 x 75 |
1 x 80 |
1 x 80 |
1 x 155 |
1 x 155 |
2 x 80 |
Defrost Type |
Electrical Heating Element |
Expansion Type |
Thermostatic Expansion Valve |
Refrigerant |
R |
R404A |
Weight |
KGS. |
57 |
60 |
62 |
87 |
90 |
117 |
120 |
150 |
Applicable Room Volume |
m3 |
3 |
5 |
7 |
10 |
18 |
24 |
30 |
40 |
|
|
MODEL: SLYCJ-___-MY-P |
33 |
50 |
63 |
100 |
125 |
175 |
200 |
275 |
350 |
Rated Cooling capacity |
BTUH |
1,808 |
2,764 |
3,583 |
5,323 |
7,609 |
10,065 |
11,089 |
15,013 |
17,743 |
Tons |
0.2 |
0.2 |
0.3 |
0.4 |
0.63 |
0.84 |
0.92 |
1.25 |
1.48 |
Watt |
530 |
810 |
1,050 |
1,560 |
2,230 |
2,950 |
3,250 |
4,400 |
5,200 |
Power Supply |
V/P/Hz |
220V / 1P / 50Hz |
|
415V / 3P / 50Hz |
Power Input |
Watt |
680 |
850 |
1,100 |
1,300 |
1,750 |
2,520 |
2,610 |
3,330 |
4,200 |
Temperature Range |
Deg. C |
-18 ~ -20 |
Condenser Fan Power Input |
Watt |
1 x 75 |
1 x 75 |
1 x 75 |
1 x 80 |
1 x 80 |
1 x 155 |
1 x 155 |
2 x 80 |
2 x 80 |
Evaporator Fan Power Input |
Watt |
1 x 75 |
1 x 75 |
1 x 75 |
1 x 80 |
1 x 80 |
1 x 155 |
1 x 155 |
2 x 80 |
2 x 80 |
Defrost Type |
Electrical Heating Element |
Expansion Type |
Thermostatic Expansion Valve |
Refrigerant |
R |
R404A |
Weight |
KGS. |
57 |
60 |
62 |
87 |
90 |
117 |
120 |
150 |
155 |
Applicable Room Volume |
m3 |
3 |
5 |
7 |
10 |
18 |
24 |
30 |
40 |
50 |
|
|
MODEL: SLYCJ-___-MY-P |
50 |
63 |
100 |
125 |
175 |
275 |
350 |
Rated Cooling capacity |
BTUH |
2,764 |
3,583 |
5,323 |
7,609 |
10,065 |
15,013 |
17,743 |
Tons |
0.2 |
0.3 |
0.4 |
0.6 |
0.84 |
1.25 |
1.48 |
Watt |
810 |
1,050 |
1,560 |
2,230 |
2,950 |
4,400 |
5,200 |
Power Supply |
V/P/Hz |
220V/1/50Hz |
415/3/50 |
Power Input |
Watt |
850 |
1,100 |
1,300 |
1,750 |
2,520 |
3,300 |
4,200 |
Temperature Range |
Deg. C |
0 - 5 |
Condenser Fan Power Input |
Watt |
1 x 75 |
1 x 75 |
1 x 80 |
1 x 80 |
1 x 80 |
2 x 80 |
2 x 80 |
Evaporator Fan Power Input |
Watt |
1 x 75 |
1 x 75 |
1 x 80 |
1 x 80 |
1 x 80 |
2 x 80 |
2 x 80 |
Defrost Type |
Electrical Heating Element |
Expansion Type |
Thermostatic Expansion Valve |
Refrigerant |
R |
R404A |
Weight |
KGS. |
73 |
75 |
118 |
122 |
145 |
190 |
195 |
Applicable Room Volume |
m3 |
5 |
7 |
10 |
18 |
24 |
40 |
50 |
|
|
MODEL: SLYCJ-___-LY-T |
50 |
63 |
100 |
150 |
200 |
300 |
Rated Cooling capacity |
BTUH |
1,877 |
2,252 |
2,559 |
3,583 |
5,391 |
7,029 |
Tons |
0.16 |
0.19 |
0.21 |
0.3 |
0.5 |
0.59 |
Watt |
550 |
660 |
750 |
1,050 |
1,580 |
2,060 |
Power Supply |
V/P/Hz |
220V/1/50Hz |
Power Input |
Watt |
850 |
1,100 |
1,300 |
1,750 |
2,520 |
3,300 |
Temperature Range |
Deg. C |
-18 ~ -20 |
Condenser Fan Power Input |
Watt |
1 x 75 |
1 x 75 |
1 x 80 |
1 x 80 |
1 x 80 |
2 x 80 |
Evaporator Fan Power Input |
Watt |
1 x 75 |
1 x 75 |
1 x 80 |
1 x 80 |
1 x 80 |
2 x 80 |
Defrost Type |
Electrical Heating Element |
Expansion Type |
Thermostatic Expansion Valve |
Refrigerant |
R |
R404A |
Weight |
KGS. |
73 |
75 |
118 |
122 |
145 |
190 |
Applicable Room Volume |
m3 |
5 |
7 |
10 |
18 |
24 |
40 |
|
NOTES: |
-
-
-
- |
The Capacity test condition of SLYCJ-___-MY is: Te / Tcon: -7 Deg. C / 45 Deg. C
The Capacity test condition of SLYCJ-___-LY is: Te / Tcon: -25 Deg. C / 45 Deg. C
The condition for chiller room selection are base on environment temperature 32 Deg C, Wall thickness of 100mm
PE, Initial temperature for goods entrance is lower than 25 Deg. C, quantity of goods put in for each day is lower
than 15% of room volume
The condition for Freezer room selection are base on environment temperature 32 Deg C, Wall thickness of 150mm
PE, Initial temperature for goods entrance is lower than -10 Deg. C, quantity of goods put in for each day is lower
than 15% of room volume |
|
|
|