Logo

Introducing Our New Products UV Lamp, Self Contain Freezer Unit and Heat Pump

AD Bar
   
        Commercial/Industrial Unit
 
Home
Air Conditional
Refrigeration
Heat Pump
Ventilation
Electrical
UV Lamp
UV Ballast
Solar Equipment
Oxygen concentrator
Contacts
 
 
 
 
Self Contain Freezer Chiller Unit
 
Features/Benefits
-

-

-
Our self cotain cooler is compact in structure. It save
installation space and cost.
The integrates evaporator, condenser, compressor
and electrical control units are in one compact body.
This unit include Heat exchangers of high efficient in
grooved copper tube with aluminum fins, The intelligent
controls are with automatic temperature set,
temperature control. The protection devices are over
loading, sub-heating, lack of phase, high & low
pressure, hot gas defrosting, Refrigerant R404a and etc.
 
Capacity Range From: 0.2 - 1.5 Tons For More Detail: Download
MODEL: SLYCJ-___-MY-P 33 50 63 100 125 175 200 275
Rated Cooling capacity BTUH 1,808 2,764 3,583 5,323 7,609 10,065 11,089 15,013
Tons 0.2 0.2 0.3 0.4 0.63 0.84 0.92 1.25
Watt 530 810 1,050 1,560 2,230 2,950 3,250 4,400
Power Supply V/P/Hz 220V / 1P / 50Hz 415V / 3P / 50Hz
Power Input Watt 680 850 1,100 1,300 1,750 2,520 2,610 3,330
Temperature Range Deg. C 0 - 5
Condenser Fan Power Input Watt 1 x 75 1 x 75 1 x 75 1 x 80 1 x 80 1 x 155 1 x 155 2 x 80
Evaporator Fan Power Input Watt 1 x 75 1 x 75 1 x 75 1 x 80 1 x 80 1 x 155 1 x 155 2 x 80
Defrost Type Electrical Heating Element
Expansion Type Thermostatic Expansion Valve
Refrigerant R R404A
Weight KGS. 57 60 62 87 90 117 120 150
Applicable Room Volume m3 3 5 7 10 18 24 30 40
 
MODEL: SLYCJ-___-MY-P 33 50 63 100 125 175 200 275 350
Rated Cooling capacity BTUH 1,808 2,764 3,583 5,323 7,609 10,065 11,089 15,013 17,743
Tons 0.2 0.2 0.3 0.4 0.63 0.84 0.92 1.25 1.48
Watt 530 810 1,050 1,560 2,230 2,950 3,250 4,400 5,200
Power Supply V/P/Hz 220V / 1P / 50Hz   415V / 3P / 50Hz
Power Input Watt 680 850 1,100 1,300 1,750 2,520 2,610 3,330 4,200
Temperature Range Deg. C -18 ~ -20
Condenser Fan Power Input Watt 1 x 75 1 x 75 1 x 75 1 x 80 1 x 80 1 x 155 1 x 155 2 x 80 2 x 80
Evaporator Fan Power Input Watt 1 x 75 1 x 75 1 x 75 1 x 80 1 x 80 1 x 155 1 x 155 2 x 80 2 x 80
Defrost Type Electrical Heating Element
Expansion Type Thermostatic Expansion Valve
Refrigerant R R404A
Weight KGS. 57 60 62 87 90 117 120 150 155
Applicable Room Volume m3 3 5 7 10 18 24 30 40 50
 
MODEL: SLYCJ-___-MY-P 50 63 100 125 175 275 350
Rated Cooling capacity BTUH 2,764 3,583 5,323 7,609 10,065 15,013 17,743
Tons 0.2 0.3 0.4 0.6 0.84 1.25 1.48
Watt 810 1,050 1,560 2,230 2,950 4,400 5,200
Power Supply V/P/Hz 220V/1/50Hz 415/3/50
Power Input Watt 850 1,100 1,300 1,750 2,520 3,300 4,200
Temperature Range Deg. C 0 - 5
Condenser Fan Power Input Watt 1 x 75 1 x 75 1 x 80 1 x 80 1 x 80 2 x 80 2 x 80
Evaporator Fan Power Input Watt 1 x 75 1 x 75 1 x 80 1 x 80 1 x 80 2 x 80 2 x 80
Defrost Type Electrical Heating Element
Expansion Type Thermostatic Expansion Valve
Refrigerant R R404A
Weight KGS. 73 75 118 122 145 190 195
Applicable Room Volume m3 5 7 10 18 24 40 50
 
MODEL: SLYCJ-___-LY-T 50 63 100 150 200 300
Rated Cooling capacity BTUH 1,877 2,252 2,559 3,583 5,391 7,029
Tons 0.16 0.19 0.21 0.3 0.5 0.59
Watt 550 660 750 1,050 1,580 2,060
Power Supply V/P/Hz 220V/1/50Hz
Power Input Watt 850 1,100 1,300 1,750 2,520 3,300
Temperature Range Deg. C -18 ~ -20
Condenser Fan Power Input Watt 1 x 75 1 x 75 1 x 80 1 x 80 1 x 80 2 x 80
Evaporator Fan Power Input Watt 1 x 75 1 x 75 1 x 80 1 x 80 1 x 80 2 x 80
Defrost Type Electrical Heating Element
Expansion Type Thermostatic Expansion Valve
Refrigerant R R404A
Weight KGS. 73 75 118 122 145 190
Applicable Room Volume m3 5 7 10 18 24 40
NOTES:
-
-
-


-
The Capacity test condition of SLYCJ-___-MY is: Te / Tcon: -7 Deg. C / 45 Deg. C
The Capacity test condition of SLYCJ-___-LY is: Te / Tcon: -25 Deg. C / 45 Deg. C
The condition for chiller room selection are base on environment temperature 32 Deg C, Wall thickness of 100mm
PE, Initial temperature for goods entrance is lower than 25 Deg. C, quantity of goods put in for each day is lower
than 15% of room volume
The condition for Freezer room selection are base on environment temperature 32 Deg C, Wall thickness of 150mm
PE, Initial temperature for goods entrance is lower than -10 Deg. C, quantity of goods put in for each day is lower
than 15% of room volume
     
   
Hit Counter   Copyright ©1994-2013  
    Recommended 1024 X 768, IE 8 browser for the best browsing mode Updated on 21 June 2013